Product Card

The Manager30 comes with a choice
of displays designed to give you house
battery information and charge status
along with critical system information
while charging is in progress.
Whichever display you choose this 30
amp battery management system gives
you the best of both worlds.
Remote Battery Monitor
The Manager30 gives you a choice...
The BMS1230S3 is supplied with the
standard black and white remote monitor
which provides information such as
current, voltage and temperature as well
as a simplified battery percentage and
charge rate.
Standard display
BMS1230S3
The BMS1230S3R is supplied with
the RedVision display and provides
connectivity of the Manager30 to the
RedVision Smartphone app, allowing
monitoring of the battery state of charge
from your mobile device.
RedVision display
BMS1230S3R
The Manager30 is a complete battery management
system for charging auxiliary batteries used in
automotive applications by incorporating AC, DC and
solar inputs to achieve the best charge.
Developed with ease of installation in mind,
TheManager30 is compatible with all vehicles
and alternator systems including variable voltage
alternators, features load sharing capabilities and
greenpower priority.
Powerful output
The Manager30 comes with a massive 30 amp
currentoutput and is able to handle more power
intensive loads and maintain larger battery banks.
It can also charge all common automotive batteries
including lithium (LiFePO4).
Green Power Priority – If 12 volt solar power is
available, solar power will be used before topping
up the output charging current from another source
such as mains power or DC vehicle power when on
themove.
MPPT Solar regulator – the built-in Maximum
Power Point Tracking (MPPT) solar regulator allows
TheManager30 to deliver the maximum amount of
power from your solar panels, even during low light
conditions.
Multi-stage charging process
Two different multi-stage DC-DC charging profiles fully
charge auxiliary batteries.
Touring mode - designed for use when ‘on the road’.
It offers a 3-stage
*
charging profile consisting of boost,
absorption and float. Touring mode will charge your
auxiliary battery to its optimal level whilst allowing you
to run loads from the battery.
FloatAbsorptionBoost
Current
Voltage - Lithium
Voltage - SLA
Storage mode - designed to keep your auxiliary
battery charged whilst your caravan/camper is in
storage by using an 8-stage
*
charging profile.
Maintenance
Desulphation FloatEqualiseAbsorptionBoostSoft
Start
Battery
Test
Current
Voltage - Lithium
Voltage - SLA
Sophisticated fault detection sensors monitor the
battery conditions during all stages of charging, keeping
you and your caravan/camper safe.
Specifications
Part number BMS1230S3 BMS1230S3R
Output current 30A 30A
Charging mode Storage mode Touring mode Storage mode Touring mode
Lithium (max) 14.5V
14.5V
14.5V
14.5V
GEL setting (max) 14.4V
14.4V
14.4V
14.4V
AGM setting (max) 14.4V
14.4V
14.4V
14.4V
Calcium setting (max) 16.0V
15.2V
16.0V
15.2V
Standard lead acid (max) 15.5V
14.8V
15.5V
14.8V
Operating temperature
-40°C to +80°C -40°C to +80°C
Weight 5.5kg 5.2kg
Dimensions Main unit - 445x185x79mm
Standard display - 186x74x29mm
Main unit - 445x185x79mm
RedVision display - 178x108x26mm
EMC compliance RCM, AS/NZS, CISPR11 RCM, AS/NZS, CISPR11
Safety compliance AS/NZS 60335.2.29, AS/NZS 60335.1 AS/NZS 60335.2.29, AS/NZS 60335.1
Environmental compliance RoHS RoHS
Warranty 2 years 2 years
* Depending on the battery type some stages are omitted from theprofile.
Voltages stated above are nominal and may vary slightly from that
specified. Contact REDARC if further information is required.
The Manager30 will only charge the battery when the battery
temperature is between -25°C and +60°C for standard lead acid, AGM
and calcium batteries that are above 10.5 volts and between 0°C and
+60°C in all other circumstances.
The Manager standard installation (12 or 24 volt)
Want to know more?
Scan this QR code with
your smartphone to go
to the Redarc website
Australia
Phone (08) 8322 4848
Fax (08) 8387 2889
International
Phone +61 8 8322 4848
Fax +61 8 8387 2889
REDARC Electronics
ABN 77 136 785 092
23 Brodie Road (North)
Lonsdale, South Australia
Australia 5160
power@redarc.com.au
www.redarc.com.au
* Fuses not supplied. The size of
these load fuses relate to the
total current draw of all loads
connected to the house
battery and should be rated
slightly higher than this.
** Essential loads are loads
which must be left on at all
times (or until the battery
isflat).
Non-essential
loads are those
which can
be switched
off when the
battery reaches
a particular
low-charge level,
which can be set
in the ‘advanced
settings’ menu.
*** Either CANBus
connection can
be used for the
display or battery
sensor.
240V AC from
mains power
(rear side)
AC
MAINS
12V unregulated
solar panel
array
Solar option
THE
MANAGER
MODEL
AC INPUT
VEHICLE INPUT
SOLAR INPUT
BATTERY OUTPUT
BMS1230S3
230V, 50-60Hz, 560W
9 - 32VDC, 520W
9 - 32VDC, 520W
12VDC Nom./ 0-30A
Please refer to owners
manual for appropriate wire
gauge and fuse ratings.
The Redarc CAN system is
designed to operate Redarc
CAN based devices only.
WARNING: Before obtaining access to terminals, all supply circuits must be disconnected
30
AMPS
LITHIUM
PROFILE
start
battery
auxiliary
battery
fuse*
essential
loads**
BMS1230S3/R
+
load
disconnect
non-essential
loads**
battery
sensor***
fuse*
load
fuses*
ignition
trigger
load terminal of
BMS1230S3/R
85
86
87
30
+
+
solar
panel
Optional display
BMS1230S3R
Standard display
BMS1230S3
Visit redarc.com.au/manager
for more information. The Manager is
available at your nearest auto electrician
or 4WD specialty store.
Details and specifications are subject to change without notice.
© 2020 REDARC Electronics Pty Ltd. All rights reserved.
6607-200403