Product Manual

4
Step 4
Fit the suitable REDARC Fuse Kit (FK40 or FK60) as close as possible to the
battery according to the REDARC BCDC Instruction Manual
BCDC1220—Use FK40
BCDC1225D—Use FK40
BCDC1240D/1250D—Use FK60
Step 5
Use appropriate fasteners to suit mounting the completed bracket and charge
assembly to the vehicle in the chosen location. Take care to ensure that any
new holes are treated to prevent corrosion.
Step 6
Ensure all fasteners are tight and that the overall mounting is secure.
Removing factory fitted screws may expose bare metal resulting in rust.
Retouch any exposed metal with rust inhibitor if it is not an earth connection.
PERIODIC MAINTENANCE/CHECKS
Check the BCDC is clear of combustibles during regular servicing of the vehicle.
Build-up of combustible materials around the bracket may result in a fire hazard.
INSTALLATION