Product Manual

OPERATING INSTRUCTIONS
Setup Modes
(Setup mode is indicated by display of the programming symbol )
ID Select
Mode / Beeps: 1
Selections: 0 to 9 & A to F (16 selections)
For a single gauge setup do not change this selection as only the default selection
‘Id.0’ allows programming of modes.
Background Colour
Mode / Beeps: 2
Selections: 13 colours
Press and hold the programming button to select the colour that the gauge backlight
will display during normal operation. There are 13 different backlight colour options
Alert Colour
Mode / Beeps: 3
Selections: 2 Colours (Amber & Red)
Press and hold the programming button to select the colour that the gauge backlight
will change to when an alert is indicated (such as during a low voltage warning).
NOTE THAT THE ALERT THRESHOLDS CANNOT BE CHANGED ON THE G52-VA AND G52-VVA.
Master Battery Select
Mode / Beeps: 4
Selections: Battery 1, Battery 2, None
Ensure that this mode is always set to None (no pointer showing)
Current Sensor Display
Mode / Beeps: 5
Selections: 0.0’ or ‘nc’
CHANGING THIS SETTING FROM ‘NC’ TO 0.0 WILL RESET THE ZERO-OFFSET OF THE CURRENT
METER. ENSURE THAT NO CURRENT IS FLOWING WHILST CHANGING THIS SETTING.
If you have installed the optional current sensor (GS-AMPS) and wish to display
current, set this to ‘0.0’, otherwise set to ‘nc’.