Operation Manual

RED DSMC OPERATION GUIDE: WEAPON
COPYRIGHT © 2015 RED.COM, INC 955-0116_V6.1, REV-E | 37
INTERCHANGEABLE OLPF SYSTEM
This section describes the process for swapping an interchangeable OLPF.
WARNING: Read these instructions carefully and in their entirety before removing or installing an interchangeable
OLPF. Damage caused to the OLPF module, camera, or sensor due to improper handling or use is not covered
under warranty.
WARNING: Once an interchangeable OLPF is removed from the BRAIN, the sensor is exposed. Improper handling
of the OLPF modules or BRAIN during this procedure may compromise the installation or cause irreparable
damage to your camera or sensor.
WARNING: DO NOT allow any dirt or debris to enter the optical cavity.
WARNING: Use only WEAPON RED DRAGON OLPFs. DO NOT use DSMC OLPFs. For any questions about OLPF
compatibility, please contact your Bomb Squad representative.
SWAP AN INTERCHANGEABLE OLPF
REQUIRED TOOLS: T20 TORX driver
1. Turn off the camera.
2. Remove any modules, cables, or other accessories that may interfere with operations.
3. Loosen and remove the four (4) M4x0.7 x 8 mm lens mount screws in a cross pattern (“X” pattern) using a
T20 TORX driver.
NOTE: The DSMC Mg PL Mount 2.0 has captive screws that are not removable from the mount.
NOTE: Screw removal may require a large handle T20 TORX driver and additional leverage.
4. Remove the lens mount.
5. Use a damp, lint-free cloth to gently wipe down the area around the lens mount and OLPF module. Remove
as much dust and debris as possible.
6. Use a T20 TORX driver to turn the lock on the camera counter-clockwise to the Unlock position.
7. Remove the OLPF module and place it in its protective case.
8. Use an LED light to ensure that the optical cavity is clean and free from dust or debris.
9. Ensure the desired OLPF module is clean and free of debris.
10. Insert the OLPF module.
11. Use a T20 TORX driver to turn the lock on the camera clockwise to the Lock position.
NOTE: If the lock does not turn easily, gently press down on the OLPF module while turning the lock.
12. Replace the lens mount.
13. Replace and loosely tighten the four (4) M4x0.7 x 8 mm lens mount screws in a cross pattern (“X” pattern)
using a T20 TORX driver. DO NOT FULLY TIGHTEN.
NOTE: The DSMC Mg PL Mount 2.0 has captive screws that are not removable from the mount.
14. Fully tighten the four (4) lens mount screws in a cross pattern (“X” pattern) using a T20 TORX driver. DO
NOT exceed 350 in-oz, or damage may occur.
NOTE: DO NOT OVERTIGHTEN.