Operation Manual

Version 2.0.5R1
DECEMBER 20, 2011 ©2011 RED.COM INC.
39
GEN Green - A genlock signal compatible with the current project and monitor rates has been locked
to.
SYNC
SYNC Gray - The sensor sync mode is not Genlock.
SYNC Red - The sensor sync mode is Genlock, but it is not locked to any genlock signal.
SYNC Green - A genlock signal compatible with the current project and monitor rates has been locked
to and the sensor timing is also locked to it.
POWER STATUS
If powering camera through DC power, the current voltage will be displayed.
If using a REDBRICK or similar external battery to power the camera through DC IN, power status
displays the current supply voltage available from the battery. Supply voltage decreases as battery is
discharged, the displayed text is color coded as follows:
Green = 12.0 V and up Yellow = 11.9 11.8 V Red = 11.7 11.6 V
NOTE: The camera will automatically power down if supply voltage drops to 11.5 Volts.
If using a REDVOLT battery in the Side Handle to power the camera, power status displays the location of
the power source (example: SH: Side Handle) and reports the % of remaining battery capacity and the
displayed text is color coded as follows:
Green = 99% - 11% Yellow = 10% - 6 % Red = 5% - 0%
If using a RED BRICK battery connected to DC IN, power status displays BRICK and reports the % of
remaining battery capacity and the displayed text is color coded as follows:
Green = 99% - 11% Yellow = 10% - 6 % Red = 5% - 0%
RAW CLIP METER
The RAW Clip meter looks a traffic light style meter and indicates if either of the Red, Blue or
Green channels of the RAW sensor data are clipping. This meter is unaffected by White Balance,
ISO, VIEW or LOOK settings and therefore represents a true measurement of the exposure
levels of the sensor at all times.