Operation Manual
Version 2.0.5R1
©2011 RED.COM INC. DECEMBER 20, 2011
202 202
APPENDIX F: 3D SETUP / OPERATION
OVERVIEW
The following information outlines basic procedures to connect two (2) RED SCARLET-X cameras
together in a Master / Slave configuration for 3D operation, operation of cameras in Master / Slave
configuration and clip naming conventions for clips recorded on those cameras. The MASTER camera
will control only the METADAT parameters of both cameras. On the SLAVE camera, any other setting
outside of these will need to be manually changed before recording.
CAMERA SETUP
Select one camera to be designated as Master and a second to be designated as Slave.
NOTE: Cameras can be set up in a MASTER / MASTER and SLAVE / SLAVE configuration. To set
as MASTER / MASTER select ALL under TARGET for both cameras. This will allow either camera
to make changes and control record start/stop of both cameras. To set as SLAVE / SLAVE select
NONE under TARGET for both cameras.
MASTER CAMERA
Perform the following steps on the Master camera:
1. Go to SECONDARY MENUS > SETTINGS > SETUP > COMMUNICATION > NAME and give the
camera a unique NAME (CAM A, LEFT, etc…).
2. Under TARGET select ALL.