Operation Manual
Version 2.0.5R1 
DECEMBER 20, 2011  ©2011 RED.COM INC. 
161 
CTRL (RS232 CONTROL) 
A 4-pin LEMO connector supports RS232 remote control for stereoscopic camera image capture, and 
third party metadata ingest applications. 
The shutter Sync Output signal acts as an immediate response hardware tally of a scan. This is useful 
for 3D or motion control applications where a slave camera or lighting device needs to be synchronized 
to a master camera.  
Alternatively, this output pin may be used as a GPO (General Purpose Output) tally, whose function is 
programmed in the USER KEYS menu. Default is Record Tally. 
Figure 23: View into camera CTRL (RS232 Control) Interface connector 
Mating Connector: LEMO FGG.00.304.CLAD27Z 
PIN  SIGNAL  DESCRIPTION 
1  GROUND  Common Ground  
2  232 RX  RS232 RX 
3  SS/GPO  Shutter Sync / GPO Output 
4  232 TX   RS232 TX 
NOTE: When active, the GPO tally presents 3.3V @ 0.04 Amps maximum between pins 1 and 3. 
When used as Sync Out, the signal is rising edge pulse at start of exposure. As a Tally, it is rising 
edge at start of record, falling edge at end of record. 
NOTE: A pre-fabricated CTRL interface cable is available from RED Digital Cinema.  
•  P/N 790-0152 – RS232 – Camera to DB-9 – 3 ft. (1m) 
•  DB-9 Pin 1:  Shutter Sync / GPO 
•  DB-9 Pin 2:  RS232 Tx 
•  DB-9 Pin 3:  RS232 Rx 
•  DB-9 Pin 4:  Ground 