Operation Manual
Copyright RED Digital Cinema Apr 30 2009
62
WRITE LOG: select to write camera’s .LOG file to CF card or RED-DRIVE™ magazine. The
.LOG file is a diagnostic tool that can assist RED with camera troubleshooting. After capture,
upload the .LOG file to the RED customer service team contactable at www.red.com/support
REMOTE: This menu provides access to controls that specify the operation of the remote
ports on the camera. At this time there is a single selection - S4/I.
S4/i
Check the S4/i box to enable communication between the RED ONE™ and an S4/i compatible
lens, and to enable recording of the lens data as metadata in the RED ONE™ .R3D files.
To enable the display of Focus / Zoom / Iris data from the S4/i lens, also check the LENS DATA
checkbox located in SYSTEM / SETUP / PREFERENCES / DISPLAY menu.
Note: S4/i communications requires appropriate hardware to be present in the camera
body and P/L lens mount. Cameras shipped prior to Sept 15 2008 will require a factory
installed hardware upgrade to enable this function.