SYSTEM 
Available options are FAN CONTROL, RECORD SPEED and STANDBY SPEED as well as BEEP 
SPEAKER and EVF TALLY LIGHT. 
FAN CONTROL 
Specifies cooling fan operation. Available options are AUTO and MANUAL. Manual will run the fan at the 
speeds specified in RECORD SPEED and STANDBY SPEED. Default setting is AUTO. 
Auto 
This setting selects VARIABLE speed fan operation in standby based on the camera core temperature. 
Manual 
This setting allows you to set a fixed fan speed to be used during Record and Standby modes. 
Record Speed 
Sets a fixed fan speed to be used during Record. Range 25 – 100%. Default is 50%. 
Standby Speed 