RED START/STOP CABLE (1B TO BNC)
The RED Start/Stop Cable (1B to BNC) provides Start/Stop, Genlock, and Timecode support. This cable con-
nects to the EXP port on the W.M.D. and an auxiliary device for Start/Stop, Genlock and Timecode.
NOTE: Full support requires the 3BNC-to-00 LEMO Sync Cable and a BNC-TO–BNC Adaptor (included with the
RED 3-Axis Lens Control System).
W.M.D. EXPANSION PORT EPIC START/STOP
FGG-1B.314.CLAD42Z BNC
PIN SIGNAL WIRING PIN SIGNAL
1 GND 1-Shield Shield GND
2 232_Rx - Coax EPIC Start/Stop
3 +12 V - - -
4 232_Tx - - -
5 Momentary
Start/Stop
- - -
6 EPIC Tally - - -
7 EPIC Start/Stop 7-Coax - -
8 AUX GPIO 1_3.3 - - -
9 +3.3 V - - -
10 Cable ID - - -
11 - - - -
12 AUX GPIO 2_3.3 - - -
13 - - - -
14 - - - -
RED Start/Stop Cable (1B to BNC)