User's Manual
V7 EXTERNAL ANTENNA RTLS MODULE USER MANUAL
© 2020 Redpoint Positioning Corp. Restricted Distribution 23
OTA started, host allowed to proceed:
M H
#OTA status=on completed=1 size=256000
OTA started, host canceled operation:
1. M H
#OTA status=on completed=1 size=256000
2. H M
OTA cmd=cancel
3. M H
#OTA status=off
OTA periodic reporting:
M H
#OTA status=on completed=57 size=256000
OTA status check requested by host:
1. H M
OTA cmd=status
2. M H:
#OTA status=on completed=57 size=256000
or
1. H M :