User Manual

33
Byte (hex) Description
F7 End of Exclusive (EOX)
Properties
Firmware Version
Get Set ID 1 ID 2 Data Bytes Data
X 7F 01 8 Firmware version:
0: Major
1: Minor
2: Patch
3: Release type (ascii)
4-7: Build number
Returns the firmware version.
Error Code
Get Set ID 1 ID 2 Data Bytes Data
X 7F 0A 10 2 32-bit integers,
each encoded in 7-bit bytes
Returns a diagnostic error code that can assist Red Panda in troubleshooting problems.
Input voltage
Get Set ID 1 ID 2 Data Bytes Data
X 7F 0B 2 100 * PSU voltage in Volts
Returns the approximate input voltage. Can be useful for diagnosing power issues.
Maximum input level (headroom)
Get Set ID 1 ID 2 Data Bytes Data
X X 7F 10 1 01: +7.2 dBu max (5.0 Vpp)
02: +5.2 dBu max (4.0 Vpp) (default)
03: +0.5 dBu max (2.3 Vpp)
Adjusts the input/output gain to accommodate dierent signal levels.
Bypass mode
Get Set ID 1 ID 2 Data Bytes Data
X X 7F 11 1 01: analog bypass
02: DSP bypass
03: kill dry
Bypass mode.