User Manual

Table Of Contents
Red-M 1000AP getting started guide
15
Reading the LED
The 1000AP has a two-color LED indicator to show its
status and locate it when in Identify mode (see Using
Identify mode).
LED startup sequence
1. When power is connected, the LED is orange for
about a second to indicate that power is on.
2. The LED flashes orange for a few seconds to indicate
that the 1000AP is starting up and conducting
self-tests. If any startup tests fail, the LED changes
to steady orange to indicate a fatal error.
3. The LED illuminates steady red after startup to
indicate normal operation.
4. If the 1000AP has passed its startup tests but
cannot either connect to Genos or obtain an IP
address from a DHCP server, the LED flashes red.
5. If there is a fatal error at any time, the LED
illuminates steady orange. If it remains in this state
for more than a second, try disconnecting and
reconnecting power to the 1000AP, otherwise return
the unit to Red-M.
LED indicator status chart
Status Meaning
Steady red Normal operation
Steady orange Fault mode
Flashing orange Startup and self-testing
Flashing red Cannot locate a Genos server or obtain an IP
address. It may not be connected properly or the
Genos server may not be switched on
Rapid flashing red Upgrading software
Flashing red and
orange
Identify mode. Lets you identify a 1000AP from
the management interface