User Manual

24
PARAMETER VALUE CHART
Programmer:______________________Date:_________
Controller Number:_______ Security Code:_______
DISPLAY PARAMETER FACTORY SETTING USER SETTING

SETPOINT VALUE SP1

SETPOINT VALUE SP2
T16
P16
2
2

OUTPUT POWER PERCENT

 *
PROPORTIONAL BAND
In *
INTEGRAL TIME
T16
P16
12

 *
DERIVATIVE TIME
T16
P16

1 *
ALARM 1 VALUE
2 *
ALARM 2 VALUE
T16
P16


AUTO-TUNE START

nF

SETPOINT RAMP RATE

1
SETPOINT SELECT

USER SETTINGFACTORY SETTINGPARAMETERDISPLAY
DISPLAY LOOP
OUTPUT MODULE (2)
LOCKOUT MODULE ()
ALARM MODULE ()
COOLING MODULE (2)
HIDDEN LOOP
INPUT MODULE (1I ) T16 ONLY
INPUT MODULE (1I ) P16 ONLY
* Factory Setting places these parameters in the Hidden Loop (set to  in
Lockout Module .



1
F1 KEY FUNCTION
SETPOINT HIGH LIMIT
SHIFT/OFFSET
USER INPUT FUNCTION
SETPOINT LOW LIMIT
DIGITAL FILTERING
F1In
I
F
In

F
DECIMAL RESOLUTION

F
TEMPERATURE SCALE

j
INPUT TYPE

USER SETTINGFACTORY SETTINGPARAMETERDISPLAY
F1In
F1 KEY FUNCTION
NONE
In
USER INPUT FUNCTION
PLOC
I
SETPOINT HIGH LIMIT


SETPOINT LOW LIMIT

In2
2
In1
1
INPUT VALUE SCALING 2
DISPLAY VALUE SCALING 2
INPUT VALUE SCALING 1
DISPLAY VALUE SCALING 1
2
1


USER SETTINGDISPLAY PARAMETER FACTORY SETTING


PERCENT ANNUNCIATOR
INPUT TYPE


n
ROUNDING INCREMENT
1

DECIMAL RESOLUTION

F
DIGITAL FILTERING
1
CONTROL MODE TRANSFER

ON/OFF CONTROL HYSTERESIS
2
2

AUTO-TUNE CODE
0
n
ANALOG OUTPUT RANGE
2

CONTROL ACTION

I
ANALOG HIGH SCALING
1

ANALOG LOW SCALING


ANALOG UPDATE TIME

ANALOG OUTPUT ASSIGNMENT


OUTPUT POWER DAMPENING
T16
P16
1
USER SETTINGDISPLAY PARAMETER
FACTORY
SETTING

CYCLE TIME
2
I
OUTPUT POWER UPPER LIMIT
1

F
SENSOR FAIL POWER PRESET
OUTPUT POWER LOWER LIMIT

ALARM VALUE ACCESS
I

ACCESS CODE

SETPOINT SELECT ACCESS


RESET ALARMS ACCESS


AUTO-TUNE ACCESS
I
nF
TRANSFER CONTROL ACCESS


SETPOINT RAMP ACCESS
I
I
PID VALUE ACCESS
I
USER SETTINGDISPLAY PARAMETER
FACTORY
SETTING

SETPOINT ACCESS
I

OUTPUT POWER ACCESS
I
1
ALARM 1 STANDBY

1
ALARM 1 VALUE
2
ALARM 2 ACTION
I

2
ALARM 1 & 2 HYSTERESIS
ALARM 2 VALUE
T16
P16
2
ALARM 2 STANDBY
NO
2
ALARM 2 RESET MODE

2
ALARM 2 ANNUNCIATOR
n
1
ALARM 1 RESET MODE

USER SETTINGDISPLAY PARAMETER
FACTORY
SETTING
1
ALARM 1 ACTION
I
1
ALARM 1 ANNUNCIATOR
n
DEADBAND
2
1
RELATIVE GAIN
2
2
CYCLE TIME
2
USER SETTING
FACTORY
SETTING
PARAMETERDISPLAY

1
T16
P16
1
1
T16