Datasheet

+9-28 VDC
PWR COMMON
1
ON
*
4
2
3
INP B
INP COMM
USR
INP A
MAGNETIC PICKUP
5
4.3 INPUT WIRING
CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter
application, the power common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth
ground potential. If not, hazardous voltage may be present at the Signal or User Inputs and input common terminals. Appropriate considerations must
then be given to the potential of the input common with respect to earth ground; and the common of the plug-in cards with respect to input common.
Resistor to Limit Current
to 2.5 mA MAX.
PWR COMMON
1
2
ON
43
**
INP COMM
USR
+9-28 VDC
AC
INP B
INP A
+9-28 VDC
NPN
O.C.
PWR COMMON
1
ON
*
4
*
2
3
INP B
INP COMM
USR
INP A
PWR COMMON
1
2
3
ON
*
4
*
INP COMM
+9-28 VDC
O.C.
PNP
USR
INP B
INP A
+9-28 VDC
+5 V
COMMON
INP COMM
INP B
USR
INP A
*
4
PWR COMMON
1
ON
2
3
+9-28 VDC
PWR COMMON
1
ON
4
2
3
**
INP B
INP COMM
USR
INP A
PWR COMMON
1
2
43
ON
**
INP COMM
USR
+9-28 VDC
INP B
INP A
AC Inputs From Tach Generators, Etc.
Input A
Two Wire Proximity, Current Source
Input A
Magnetic Pickup
Input A
Current Sourcing Output
Input A
Interfacing With TTL
Input A
Current Sinking Output
Input A
Switch or Isolated Transistor; Current Sink
Input A
+9-28 VDC
4
PWR COMMON
1
2
3
ON
INP COMM
INP B
USR
INP A
Switch or Isolated Transistor; Current Source
Input A
Switch position is application dependent.
Current Sink Output; Quad/Direction
Shaded areas not recommended for counting applications.
4.4 SETPOINT (OUTPUT) WIRING
COM
N.C.
N.O.
SINGLE SETPOINT RELAY PLUG-IN CARD
COM
N.O.
N.C.
ELECTRICAL CONNECTIONS
DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD
COM
OSNK 1(2)
(30 V MAX.)
ELECTRICAL CONNECTIONS
OSNK1
OSNK2
COM
Note: Output Common is not isolated from DC Power Common. Load must
be wired between OSNK terminal and V+ of the load supply.
4.5 SERIAL COMMUNICATION WIRING
N/C
RS485
2
COMM
A+
B-
N/C
534
N/C
RS232
5
N/C
TX
N/C
43
COMM
COMM
2
RX
61 61
4.6 USB PROGRAMMING
USB PROGRAMING PLUG-IN CARD
SERIAL COMMUNICATIONS PLUG-IN CARD
RJ11 CONNECTOR PIN OUTS