Technical data
Known Limitations
BEA WebLogic Integration Release Notes 43
49 CR081906
Problem
In some cases, Oracle streaming errors are generated when loading plug-ins. By default,
the plug-ins are loaded automatically. This problem may occur when you load plug-ins
manually.
Platforms
Workaround
Restart the server
50 CR081927
Problem
When using the Format Builder, if the encoding specified for the Default Message
Format differs from the encoding specified for the Default Field Code Page, binary
generation fails.
Platforms
All
Workaround
Specify the same encoding for the Default Message Format and the Default Field Code
Page.
51 CR081986
Problem
When enabling and registering a collaboration agreement (CA) between two trading
partners using ebXML, the B2B Console hangs. However, log messages indicate that the
CA was registered with the server.
Platforms
Windows
Workaround
Open another browser to display the modified B2B Console output.
52 CR082488
Problem
The RunSamples script does not properly load the application integration and BPM
templates on a Japanese platform.
Platforms
All
Workaround
Use the US mode of WebLogic Server by changing the code page to US ASCII. (On
Japanese Windows systems, run
us.bat to change the code page.) Then run the
RunSamples script, which automatically loads the application integration and BPM
templates.