Installation guide
Sun StorageTek Common Array Manager Software Release Notes 47
A/2 A Up FC 2 Gbps 20:04:00:A0:B8:2F:BC:3C
B/1 B Up FC 2 Gbps 20:05:00:A0:B8:2F:BC:3B
B/2 B Up FC 2 Gbps 20:05:00:A0:B8:2F:BC:3C
c. Correlate WWN’s
In this example, Port A/2 exposes c9t0d31 and Port B/2 exposes c8t0d31
Array Removal Might Not Complete Successfully
Bug 6593318 – When a number of in-band managed arrays are selected for removal,
the operation appears to complete successfully. However, one array may still be
listed on the Storage System Summary page.
Controller Resetting Issues on an In-band Managed Array
Note – For best performance, ensure both controllers are connected during
configuration.
Bug 6603978 –The controller for an in-band managed array cannot not be reset even
when physical connectivity between the array and the management host has been
verified.
Workaround –If physical connectivity is valid, un-register and re-register the array.
Error: Could not Communicate with Controller to Complete Request
Bugs 6610504, 6609734, 6609155, 6607104, 6609732, 6612120 –An occasional problem
exists where the in-band proxy agent may return the paths to the controllers in
reverse order. This error can occur on any platform.
The net result is an immediate communications error. The error message will
typically read “Error: Could not communicate with the controller to complete this
request. Possible causes include network or connection problems, controller
problems, or no power to the host or storage array. Check these possible causes, then
retry the operation.”
This error might occur when performing the following operations:.
■ volume expansion
■ snapshot copy, re-snap and disable
■ virtual disk defragmentation