Sun StorageTek Common Array Manager Software Release Notes 37
CLI - sscs list fru Command does not list FLX240 and FLX280 Fans
Bug 6587666 –The CLI command sscs list fru does not list the number of fans
installed on the Sun StorageTek FLX240 and FLX280 arrays.
Workaround –Use the Common Array Manager to view the number of fans
installed.
CLI Command sscs switch type Command Options not yet
Implemented
Bug 6584193 –Although type generic and type vlac are listed as options with the CLI
sscs switch command, these options are not yet implemented.
Communication Test May Return False Results
Bug 6597344 –Clicking the Test Communications button for an offline controller may
erroneously report that the communications test has passed.
Workaround –Verify a controller’s offline state by viewing its alarms.
Disabled Snapshot can be Reenabled after a Firmware Update
Bug 6529172 –A snapshot volume that is disabled can be automatically reenabled
after a firmware update occurs. If the snapshot volume is full, it can start generating
warning events.
Workaround–Disable the snapshot again after the firmware update.
Event List Shows Different Events but Alarms are Consistent
Bug 6612858 –The Event list from two different hosts against the same array shows
different events, even though the alarms generated are consistent.
Workaround –To display results based on the polling frequency and polling times of
the arrays, select the Advanced Aggregation Filter option from the CAM Events
page. When this option is de-selected, all hosts show consistent output. Therefore,
this is working as designed.