Installation guide

IP Address The IP address assigned to the device.
Login The login name used to access the device.
Password The password used to authenticate the connection to the device.
Password
Script
(optional)
The script that supplies a password for access to the fence device. Using this
supersedes the Passwo rd parameter.
Port The switch outlet number.
fence_mcdat
a
The fence agent for McData FC switches.
Field Descrip t io n
T ab le B.20. Q Log ic SANB o x2 Swit ch
Field Descrip t io n
Name A name for the SANBox2 device connected to the cluster.
IP Address The IP address assigned to the device.
Login The login name used to access the device.
Password The password used to authenticate the connection to the device.
Password
Script
(optional)
The script that supplies a password for access to the fence device. Using this
supersedes the Passwo rd parameter.
Power wait Number of seconds to wait after issuing a power off or power on command.
Port The switch outlet number.
fence_sanbo
x2
The fence agent for QLogic SANBox2 FC switches.
T ab le B.21. RH EV-M REST API ( R HEL 5.8 an d lat er ag ain st RHEV 3.0 an d lat er)
Field Descrip t io n
Name Name of the RHEV-M REST API fencing device.
IP Address The IP address or hostname assigned to the device.
IP port
(optional)
The TCP port to use for connection with the device.
Login The login name used to access the device.
Password The password used to authenticate the connection to the device.
Password
Script
(optional)
The script that supplies a password for access to the fence device. Using this
supersedes the Passwo rd parameter.
Use SSL
connections
Use SSL connections to communicate with the device.
Power wait Number of seconds to wait after issuing a power off or power on command.
Port Physical plug number or name of virtual machine.
fence_rhevm
The fence agent for RHEV-M REST API.
T ab le B.22. RPS- 10 Po wer Swit ch ( t wo - n o d e clu st ers o n ly)
Field Descrip t io n
Name A name for the WTI RPS-10 power switch connected to the cluster.
Device Name The device name of the device the switch is connected to on the controlling host
(for example,
/dev/ttys2
).
Red Hat Ent erprise Linux 5 Clust er Administ rat ion
96