Service manual

Chapter 4 Diagnostics
40
To correct this:
1. If additional memory was just installed in your NetServer,
please verify the installation conforms to the description in the
User's Guide.
2. If this error was reported when no additional memory was just
installed, restart the NetServer.
3. If the error persists, contact your service representative.
0713 Incorrect DIMM
installed
POST has detected one or more DIMMs are not the correct type, or
the correct speed.
To correct this:
1. If additional memory was just installed in your NetServer,
please verify the correct DIMM type and speed for this
NetServer was installed. Refer to the DIMM description in the
User's Guide.
2. If this error was reported when no additional memory was just
installed, restart the NetServer.
3. If the error persists, contact your service representative.
0800 Cache memory
size error
POST has detected the cache memory size is smaller than previously
detected.
To correct this:
1. If the processor module has just been replaced, press <F4> to
automatically validate the change.
2. If the problem persists, the processor module may need to be
replaced.
0801 Cache boot
error
POST has detected an error in the cache memory module.
To correct this:
1. Verify the processor module is installed correctly. Refer to the
User's Guide for handling precautions.
2. If the problem persists, the processor module may need to be
replaced. Contact your service representative.
0900 Integrated LAN
disable error
The system could not disable the integrated LAN.
To correct this:
1. Reset the Integrated LAN by powering off the HP NetServer.
2. Disconnecting the power cord for 20 seconds.
3. Reconnect the power cord and power on the HP NetServer.
4. If the error appears upon restarting, update the system BIOS.
5. Insert the HP Navigator CD-ROM in the CD-ROM drive and
power-cycle your system.
This will initialize the flash utility on HP Navigator CD-ROM.