Service manual

Chapter 4 Diagnostics
36
0201 Parallel Port
Controller
resource
conflict
POST has detected an address space or IRQ resource conflict
between the integrated parallel port controller and an accessory board.
To correct this:
1. If the integrated parallel port is not needed, run the Setup
Utility and disable the parallel port.
2. If the integrated parallel port is needed and its settings cannot
be modified, the accessory board's IRQ and address space
must be reconfigured to use other free resources. Refer to the
accessory board installation manual for information.
0300 Flexible disk
drive (A) boot
error
POST has detected the flexible disk drive (A) reported an error during
its self-test.
To correct this:
1. Verify a diskette can be properly inserted and removed from
the flexible disk drive.
2. Verify the flexible drive type configured in the Setup Utility
matches the flexible disk drive installed in the HP NetServer.
3. Verify all data cables and power cables are firmly connected.
4. If the problem persists, your flexible disk drive may need to be
replaced. Contact your service representative.
0301 Flexible disk
drive B boot
error
(This does not
apply to the LC
2000)
POST has detected the flexible disk drive B reported an error during
its self-test.
1. Verify a diskette can be properly inserted and removed from
the flexible disk drive.
2. Verify the flexible drive type configured in the Setup Utility
matches the flexible disk drive installed in the HP NetServer.
3. Verify all data cables and power cables are firmly connected.
4. If the problem persists, your flexible disk drive may need to be
replaced. Contact your service representative.
0305 Flexible Disk
Drive Cable
conflict
(This does not
apply to the LC
2000)
The flexible disk drive A is connected to the connector configured for
flexible disk drive B.
1. Run Setup Utility by pressing <F2>. In the flexible disk drive
section, enable the A & B flexible disk swap.
2. Alternatively, if the connector allows it, connect the flexible
disk drive to the other connector on the flexible disk drive
cable.
0306 Flexible disk
drive controller
boot error
POST has detected a general failure on the integrated flexible disk
controller.
To verify this:
1. Restart your HP NetServer.
2. If the error persists, your system board may need to be