Service manual

Chapter 2 System Information
15
HP NetServer LC 2000/2000r Power Ratings
AC Input
Voltages
Maximum Input
Power (VA)
Maximum Input
Power (W)
Maximum Operating
Current RMS (AMPS)
100 VAC 545 540 5.5
120 VAC 531 525 4.5
208 VAC 516 506 2.5
230/240 VAC 514 504 2.3
Power Supply
AC Voltage selection for this NetServer is automatically determined by the power supply.
Power Supply Requirements (Single Unit)
AC Input Power (50/60 Hz):
100 to 127 VAC, 5.5 A
200 to 240 VAC, 2.6 A
Maximum Continuous
Input Power:
540 watts maximum
Output Power:
349 watts maximum
The power cord set found in the shipping box has been approved for use in the country where the NetServer
was purchased. If any other power cord set is used, it must meet appropriate safety requirements in the
country in which the NetServer is to be used.
General Cord Set Requirements
250 VAC, 10 A
Cord set
(Approved or recognized by safety agency in country of use.
125 VAC, 10 A
Maximum length:
2.4 m (8 ft)
Environmental Requirements
The specifications listed below can vary if you install a mass storage device in your HP NetServer that has
more stringent environmental limits. Ensure the operating environment is suitable for all mass storage
devices in use.
BTU
1845 BTU/hr maximum
Temperature
Operating:
5° C to 35°C (41°F to 95° F)
Non-operating:
–40° C to +65° C (–40° F to +149° F)
Humidity
Operating:
20% to 80% relative humidity (non-condensing)
Non-operating:
5% to 95% relative humidity (non-condensing)
Altitude