Installation guide

High-End Arrays
107
MegaCli64 -LDSetProp -DisDskCache -Lall -aALL
Note
Hardware RAID cards recharge their batteries while the system is operational. If a system is
powered off for an extended period of time, the batteries will lose their charge, leaving stored data
vulnerable during a power failure.
High-End Arrays
High-end arrays have various ways of protecting data in the event of a power failure. As such, there is
no need to verify the state of the internal drives in external RAID storage.
NFS
NFS clients do not need to enable write barriers, since data integrity is handled by the NFS server
side. As such, NFS servers should be configured to ensure data persistence throughout a power loss
(whether through write barriers or other means).