Installation guide

Table B.3. Bull PAP (Platform Administration Processor)
Field Description
Name A name for the Bull PAP system connected to the cluster.
IP Address The IP address assigned to the PAP console.
Login The login name used to access the PAP console.
Password The password used to authenticate the connection to the PAP console.
Password
Script
(optional)
The script that supplies a password for access to the fence device. Using this
supersedes the Password parameter.
Domain Domain of the Bull PAP system to power cycle.
Table B.4 . Dell DRAC
Field Description
Name The name assigned to the DRAC.
IP Address The IP address assigned to the DRAC.
Login The login name used to access the DRAC.
Password The password used to authenticate the connection to the DRAC.
Module name (optional) The module name for the DRAC when you have multiple DRAC modules.
Password
Script
(optional)
The script that supplies a password for access to the fence device. Using this
supersedes the Password parameter.
Use SSH
(DRAC5 only)
(Rhel 4.8 and later) Indicates that system will use SSH to access the device.
Table B.5. Egenera SAN Controller
Field Description
Name A name for the BladeFrame device connected to the cluster.
CServer The hostname (and optionally the username in the form of usernam e@ hostnam e)
assigned to the device. Refer to the fence_egenera(8) man page for more
information.
ESH Path
(optional)
The path to the esh command on the cserver (default is /opt/pan- mgr/bin/esh)
lpan The logical process area network (LPAN) of the device.
pserver The processing blade (pserver) name of the device.
Red Hat Enterprise Linux 4 Cluster Administration