Specifications

6
Subject to change without notice
1 Installation and safety instructions
1.1 Settinguptheinstrument
As can be seen from the gures, the handle can be set into
different positions:
A and B = carrying
C = horizontal operating
D and E = operating at different angles
F = handle removal
G = operating using the feet‘s, batch use and for shipping in
original packaging
Attention!
When changing the handle position, the instrument
must be placed so that it cannot fall (e.g. placed on a
table). Then the handle locking knobs must be simul-
taneously pulled outwards and rotated to the required
position. Without pulling the locking knobs they will
latch in into the next locking position.
Removal/tting of the handle: The handle can be removed in
position F, pulling the side parts outside the housing. Adding
the handle works vice versa.
1.2 Safety
The instrument fulls the VDE 0411 part 1 regulations for
electrical measuring, control and laboratory instruments and
was manufactured and tested accordingly. It left the factory in
perfect safe condition. Hence it also corresponds to European
Standard EN 61010-1 and International Standard IEC 1010-1.
In order to maintain this condition and to ensure safe opera-
tion the user is required to observe the warnings and other
directions for use in this manual. Housing, chassis as well as
all measuring terminals are connected to safety ground of the
mains. All accessible metal parts were tested against the mains
with 2200 V
DC
. The instrument conforms to safety class I. The
oscilloscope may only be operated from mains outlets with a
safety ground connector. The mains plug has to be installed
prior to connecting any signals. It is prohibited to separate the
safety ground connection. If suspected that safe operation may
not be guaranteed do not use the instrument any more and lock
it away in a secure place.
Safe operation may be endangered if any of the following was
noticed:
in case of visible damage.
in case loose parts were noticed
if it does not function any more.
after prolonged storage under unfavourable conditions (e.g.
like in the open or in moist atmosphere).
after any improper transport (e.g. insufcient packing not
G
HMO2524E/140110/ce · Subject to changes · © HAMEG Instruments GmbH
®
· DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info@hameg.com
www.hameg.com
Mathematic functions
Number of formula sets: 5 formula sets with up to 5 formulas each
Sources: All channels and math. memories
Targets: Math. memories
Functions: ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS, NEG,
INV, INTG, DIFF, SQR, MIN, MAX, LOG, EXP
Display: Up to 4 math. memories with label
Pass/Fail functions
Sources: All channels and math. memories
Type of test: Mask around a signal, userdefined tolerance
Functions: Stop and/or Beep for Pass or Fail,
Count up to 1Mio events, including number
of Pass and Fail
General Information
Probe ADJ Output: 1kHz/1MHz square wave signal ca. 1 V
pp
(ta ‹ 4ns)
Bus Signal Source: Three outputs (frontside) which generates a
selection of serial or parallel data for test
and training purposes
Internal RTC (Realtime clock): Date and time for stored data
Line voltage: 105...253V, 50/60Hz, CAT II
Power consumption: Max. 70Watt at 230V, 50Hz
Protective system: Safety class I (EN61010-1)
Operating temperature: +5...+40°C
Storage temperature: -20...+70°C
Rel. humidity: 5...80% (non condensing)
Dimensions (W x H x D): 285x175 x220mm
Weight: 3.6kg
Accessories supplied: Line cord, Operating manual, 4 Probes, 10:1 with
attenuation ID (HZ350), Dual-Interface USB/RS-232 (HO720), CD
Optional accessories:
HOO10 Serial bus trigger and hardware acelerated decode , I
2
C, SPI,
UART/RS-232 on Logic channels
HO3508 active 8 Channel Logic Probe
HO3516 2x HO3508, active 8 Channel Logic Probes
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB) galvanically isolated
HZ355 Slimline Probe 10:1 with automatically identification
HZ355DU Upgrade from 2x HZ350 to 2x HZ355
HZ46 4RU 19'' Rackmount Kit
HZO20 High Voltage probe 1000:1 (400 MHz)
HZO30 single ended active probe (1GHz)
HZO50 AC/ DC Currentprobe 20 A, DC…100 kHz
HZO51 AC/ DC Currentprobe 1000 A, DC…20 kHz
additional accessories you can find at www.hameg.com/HMO2524
HMO2524E/140110/ce · Subject to changes · © HAMEG Instruments GmbH
®
· DQS-certified in accordance with DIN EN ISO 9001:2000, Reg.-No.: DE-071040 QM
HAMEG Instruments GmbH · Industriestr. 6 · D-63533 Mainhausen · Tel +49 (0) 6182 800 0 · Fax +49 (0) 6182 800 100 · www.hameg.com · info@hameg.com
www.hameg.com
Mathematic functions
Number of formula sets: 5 formula sets with up to 5 formulas each
Sources: All channels and math. memories
Targets: Math. memories
Functions: ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS, NEG,
INV, INTG, DIFF, SQR, MIN, MAX, LOG, EXP
Display: Up to 4 math. memories with label
Pass/Fail functions
Sources: All channels and math. memories
Type of test: Mask around a signal, userdefined tolerance
Functions: Stop and/or Beep for Pass or Fail,
Count up to 1Mio events, including number
of Pass and Fail
General Information
Probe ADJ Output: 1kHz/1MHz square wave signal ca. 1 V
pp
(ta ‹ 4ns)
Bus Signal Source: Three outputs (frontside) which generates a
selection of serial or parallel data for test
and training purposes
Internal RTC (Realtime clock): Date and time for stored data
Line voltage: 105...253V, 50/60Hz, CAT II
Power consumption: Max. 70Watt at 230V, 50Hz
Protective system: Safety class I (EN61010-1)
Operating temperature: +5...+40°C
Storage temperature: -20...+70°C
Rel. humidity: 5...80% (non condensing)
Dimensions (W x H x D): 285x175 x220mm
Weight: 3.6kg
Accessories supplied: Line cord, Operating manual, 4 Probes, 10:1 with
attenuation ID (HZ350), Dual-Interface USB/RS-232 (HO720), CD
Optional accessories:
HOO10 Serial bus trigger and hardware acelerated decode , I
2
C, SPI,
UART/RS-232 on Logic channels
HO3508 active 8 Channel Logic Probe
HO3516 2x HO3508, active 8 Channel Logic Probes
HO730 Dual-Interface Ethernet/USB
HO740 Interface IEEE-488 (GPIB) galvanically isolated
HZ355 Slimline Probe 10:1 with automatically identification
HZ355DU Upgrade from 2x HZ350 to 2x HZ355
HZ46 4RU 19'' Rackmount Kit
HZO20 High Voltage probe 1000:1 (400 MHz)
HZO30 single ended active probe (1GHz)
HZO50 AC/ DC Currentprobe 20 A, DC…100 kHz
HZO51 AC/ DC Currentprobe 1000 A, DC…20 kHz
additional accessories you can find at www.hameg.com/HMO2524
Installation and safety instructions
Installation and safety instructions
Carrying positionsOperating positions
Removing the handle (Pos. F)
Stacking positions
E
D
C
A
B
A
B
C
D
E
F
G
Positions of the instrument