Installation guide

72
EMC NetWorker Release 8.1 SP1 Installation Guide
AIX Installation
6. If the installation process detects an existing database, type y to retain the existing
database when prompted.
7. If the installation process detects a NetWorker 7.6.x Console server database:
a. To proceed with the installation and Console server database conversion, type y.
b. Specify the directory location for the database backup file.
For example:
/opt/lgtonmc/lgto_gstdb
If the conversion fails the following error message appears:
Install failed to upgrade the database
full_path_and_database name
.
Check the upgrade log
full_path_and
_
log_name_file
for details.
Please, fix any environment related errors mentioned in the log and
then run the script <full path to gstdbupgrade.sh>
manually to upgrade the database after the install is complete.
8. Specify the location of the
NetWorker
binaries.
For example
/usr/bin
9. When prompted to start the Console server daemons:
•If the database conversion is successful, type y.
If the database conversion encountered errors, type n. “Reviewing the Console
server database conversion status” on page 47 describes how to determine the
cause of the conversion failure and the steps to convert the database after the
software install has completed.
10. Update the MANPATH variable for the Console server man pages.
For example:
MANPATH=$MANPATH:/opt/lgtonmc/man
export MANPATH
11. “Connecting to the Console server GUI for the first time” on page 132 describes on
how connect to the Console server for the first time.
Uninstalling the NetWorker and Console server software on AIX
Use installp or smitty to uninstall the NetWorker software.
To uninstall the NetWorker software:
1. Log in to the target host as root.
2. Use the lslpp command to get a list of installed NetWorker software packages:
lslpp -L all | grep -i lgto*
3. Use installp -u to remove the software packages:
installp -u
package [package]...
Table 12 on page 73 provides a list of the installed packages for each installation type.