Installation guide
EMC NetWorker Release 8.1 SP1 Installation Guide
71
AIX Installation
4. Use the installp program to install the Console server software from the system
prompt:
installp -a -d
/dir_pathname
LGTOnw.clnt.rte
LGTOnmc.rte
[packages]...
where:
•
/dir_pathname
is the complete pathname of the directory that contains the
installation software.
For example, if you extracted the NetWorker software packages to the /software
directory, the dir_pathname is /software/aixpower.
•
Specify the LGTOnw.clnt.rte
only if you did not previously install the NetWorker
client package.
•
[packages]...
is a list of the optional software packages.
For example, to install the Console server software with the French language pack and
the NetWorker client software package, type:
installp -a -d /software/aixpower LGTOnw.clnt.rte LGTOnmc.rte
LGTOnw.fr.rte
5. Confirm that the required package installation completed successfully:
lslpp -L all | grep -i lgto*
Configuring the Console server software
Use the nmc_config command to configure the Console server software program.
To configure the console server software:
1. From a system prompt, type:
/opt/lgtonmc/bin/nmc_config
2. Specify a non-root user/group with limited privileges. The Console server uses this
user/group to run the web server. For example, use the default user/group
[nobody/nobody].
3. For the web server port number, use the default port number (9000) or use a custom
port number.
Valid port numbers are between 1024 and 49151.
4. For the Console server, use the default port number (9001) or use a custom port
number. Valid port numbers are between 1024 and 49151.
Do
not
use port numbers that are already in use. For example: The Console server
uses port 2638 for TDS protocol communications with the Console database. The
preferred port for EMC Data Protection Advisor product is 9002.
5. Specify the directory to use for the lgtonmc database.
For example:
/opt/lgtonmc/lgto_gstdb