EMC NetWorker Release 8.1 SP1 Installation Guide
Updating from a previous release
Updating NetWorker from 7.6.x
When updating the NetWorker software from 7.6.x, some Linux operating systems and the
Windows operating system allows you to update the NetWorker software without removing
the previous version. For HP-UX, AIX, Debian, and Ubuntu you must remove the previous
version of the NetWorker software, then install the newer version.

After you update the NetWorker server, restart the NetWorker services.
The NetWorker 7.6.x and earlier installation process made modifications to syslog.conf file
on UNIX hosts. The uninstall process removes entries made to this file. Before you remove
the NetWorker software, back up the syslog.conf file.
The NetWorker 8.1 and later installation process does not modify the syslog.conf file.

Update each NetWorker storage node before you update the NetWorker server.
These sections describe how to update the NetWorker server, the storage node, the client,
and the Console server software from 7.6.x:
“Determining the NetWorker version on the storage nodes” on page 40
“Console server requirements” on page 41
“UNIX only, backing up the configuration files” on page 42
RHEL Linux only, enabling SELinux 43
“Optional, moving the Console server files to a new Console server” on page 43
“Updating NetWorker on RHEL, RedFlag, Oracle Enterprise Server, RedFlag Asianux,
SuSE, Fedora and CentOS” on page 44
“Updating NetWorker on AIX, HP-UX, Debian, Ubuntu, MAC-OSX, and Solaris” on
page 72
“Updating NetWorker and Console server on Windows” on page 38
“Reviewing the Console server database conversion status” on page 47
“For Console server updates only, reconfiguring LDAP” on page 49
“UNIX only, retaining startup script customizations” on page 49
“NetWorker server only, updating the Clone Storage Node attribute” on page 50
“Optional, converting VCB client backups to VADP” on page 51
“Confirming the update of all storage nodes” on page 51
“Authorizing the NetWorker server” on page 51
Determining the NetWorker version on the storage nodes
A NetWorker 8.1 server disables NetWorker 7.6.x and earlier storage nodes. Before you
update the NetWorker server software, update each NetWorker storage node.
Use the nsradmin program as root on UNIX or as administrator on Windows to determine
the NetWorker version installed on the storage nodes in a datazone:
1. From a command prompt, type: