Installation guide
124
EMC NetWorker Release 8.1 SP1 Installation Guide
Microsoft Windows Installation
• Manually remove the following directories:
– C: \Program Files\EMC NetWorker\nsr\mm
– C:\Program Files\EMC NetWorker\nsr\index
– C:\Program Files\EMC NetWorker\nsr\res\resdb
◆
When a NetWorker storage node is changed to a NetWorker client, modify the
following resource attributes on the NetWorker server:
• Remove the Media Pool device restrictions that are defined for devices on the
storage node.
• On the Devices window of NMC, remove all of the storage node devices.
• On the Client Properties window, under the Globals (2 of 2) tab, update the
following attributes for each client, as required:
–Storage nodes
– Recover storage nodes
• On the Storage node properties window under the Configuration tab, update the
Clone storage nodes attribute for all of the storage nodes, as required.
Performing a silent install
You can use the setup.exe program to perform a silent or unattended installation of the
NetWorker storage node and client software.
1. From a command prompt, navigate to the setup.exe program in the directory where
you extracted the NetWorker installation software.
2. Use the setup.exe command to install the software:
setup.exe /S /v" /qn /l*v
filename.log
INSTALLLEVEL=
Type_of_Install
NW_INSTALLLEVEL=
Type_of_Install
INSTALLDIR=
directory
NW_FIREWALL_CONFIG=
[0/1]
STARTSVC=
[0/1]
setuptype=Install”
where:
•
filename.log
is the name of the file to log installation messages. The installation
process creates the log file in the same directory that you run setup.exe. When you
omit /l*v
filename.log
, the installation process does not log messages.
•
Type_of_install
specifies the
level associated with the NetWorker installation type:
– 100 is the install level for a client
– 200 is the install level for a storage node
– 300 is the install level for a server
•
directory
specifies the location to install the NetWorker software. Create this
directory location before you run the silent install. When you omit
INSTALLDIR=
directory
, the NetWorker software uses the default installation
directory: C:\Program Files\EMC NetWorker\nsr.