Installation guide

lu ci Field cl uster.co n
f At t rib u t e
Descrip t io n
Name name A name for the IBM BladeCenter device connected to the cluster.
IP Address or
Hostname
i pad d r The IP address or hostname assigned to the device.
IP port
(optional)
i ppo rt TCP port to use for connection with the device.
Login l o g i n The login name used to access the device.
Password passwd The password used to authenticate the connection to the device.
Password
Script
(optional)
passwd _scri
pt
The script that supplies a password for access to the fence
device. Using this supersedes the Passwo rd parameter.
Power Wait
(seconds)
po wer_wai t Number of seconds to wait after issuing a power off or power on
command.
Power Timeout
(seconds)
po wer_timeo
ut
Number of seconds to wait before testing for a status change
after issuing a power on or power on command. The default
value is 20.
Shell Timeout
(seconds)
shell _ti me
o ut
Number of seconds to wait for a command prompt after issuing a
command. The default value is 3.
Login Timeout
(seconds)
l o g i n_ti me
o ut
Number of seconds to wait for a command prompt after login.
The default value is 5.
Times to Retry
Power On
Operation
retry_on Number of attempts to retry a power on operation. The default
value is 1.
Use SSH secure Indicates that system will use SSH to access the device. When
using SSH, you must specify either a password, a password
script, or an identity file.
SSH Options ssh_o pti o ns SSH options to use. The default value is -1 -c bl o wfi sh.
Path to SSH
Identity File
i d enti ty_fi
l e
The identity file for SSH.
Table A.18, “ IBM BladeCenter SNMP lists the fence device parameters used by fence_i bmbl ad e,
the fence agent for IBM BladeCenter over SNMP.
T ab le A.18. IBM B lad eCen t er SN MP
lu ci Field cl uster.co n
f At t rib u t e
Descrip t io n
Name name A name for the IBM BladeCenter SNMP device connected to the
cluster.
IP Address or
Hostname
i pad d r The IP address or hostname assigned to the device.
UDP/TCP Port
(optional)
ud ppo rt UDP/TCP port to use for connections with the device; the default
value is 161.
Login l o g i n The login name used to access the device.
Password passwd The password used to authenticate the connection to the device.
Password
Script
(optional)
passwd _scri
pt
The script that supplies a password for access to the fence
device. Using this supersedes the Passwo rd parameter.
SNMP Version snmp_versi o
n
The SNMP version to use (1, 2c, 3); the default value is 1.
Red Hat Ent erprise Linux 6 Clust er Administ rat ion
182