Installation guide
Login Timeout
(seconds)
l o g i n_ti me
o ut
Number of seconds to wait for a command prompt after login.
The default value is 5.
Times to Retry
Power On
Operation
retry_on Number of attempts to retry a power on operation. The default
value is 1.
lu ci Field cl uster.co n
f At t rib u t e
Descrip t io n
Table A.16, “ HP iLO (Integrated Lights Out) MP” lists the fence device parameters used by
fence_i l o _mp, the fence agent for HP iLO MP devices.
T ab le A.16 . HP iLO ( In t eg rat ed Lig h t s O u t ) MP
lu ci Field cl uster.co n
f At t rib u t e
Descrip t io n
Name name A name for the server with HP iLO support.
IP Address or
Hostname
i pad d r The IP address or hostname assigned to the device.
IP Port
(optional)
i ppo rt TCP port to use for connection with the device.
Login l o g i n The login name used to access the device.
Password passwd The password used to authenticate the connection to the device.
Password
Script
(optional)
passwd _scri
pt
The script that supplies a password for access to the fence
device. Using this supersedes the Passwo rd parameter.
Use SSH secure Indicates that the system will use SSH to access the device.
When using SSH, you must specify either a password, a
password script, or an identity file.
SSH Options ssh_o pti o ns SSH options to use. The default value is -1 -c bl o wfi sh.
Path to SSH
Identity File
i d enti ty_fi
l e
The Identity file for SSH.
Force
Command
Prompt
cmd _pro mpt The command prompt to use. The default value is ’MP>’, ’hpiLO-
>’.
Power Wait
(seconds)
po wer_wai t Number of seconds to wait after issuing a power off or power on
command.
Delay
(seconds)
d el ay The number of seconds to wait before fencing is started. The
default value is 0.
Power Timeout
(seconds)
po wer_timeo
ut
Number of seconds to wait before testing for a status change
after issuing a power on or power on command. The default
value is 20.
Shell Timeout
(seconds)
shell _ti me
o ut
Number of seconds to wait for a command prompt after issuing a
command. The default value is 3.
Login Timeout
(seconds)
l o g i n_ti me
o ut
Number of seconds to wait for a command prompt after login.
The default value is 5.
Times to Retry
Power On
Operation
retry_on Number of attempts to retry a power on operation. The default
value is 1.
Table A.17, “ IBM BladeCenter” lists the fence device parameters used by fence_bl ad ecenter, the
fence agent for IBM BladeCenter.
T ab le A.17. IBM B lad eCen t er
Fence Device Paramet ers
181