Installation guide

IP Address or
Hostname
i pad d r The hostname assigned to the device.
Login l o g i n The login name used to access the device.
Password passwd The password used to authenticate the connection to the device.
Password
Script
(optional)
passwd _scri
pt
The script that supplies a password for access to the fence
device. Using this supersedes the Passwo rd parameter.
TCP Port i ppo rt The port number on which the telnet service listens. The default
value is 3172.
Force
Command
Prompt
cmd _pro mpt The command prompt to use. The default value is\$.
Power Wait
(seconds)
po wer_wai t Number of seconds to wait after issuing a power off or power on
command.
Delay
(seconds)
d el ay The number of seconds to wait before fencing is started. The
default value is 0.
Power Timeout
(seconds)
po wer_timeo
ut
Number of seconds to wait before testing for a status change
after issuing a power on or power on command. The default
value is 20.
Shell Timeout
(seconds)
shell _ti me
o ut
Number of seconds to wait for a command prompt after issuing a
command. The default value is 3.
Login Timeout
(seconds)
l o g i n_ti me
o ut
Number of seconds to wait for a command prompt after login.
The default value is 5.
Times to Retry
Power On
Operation
retry_on Number of attempts to retry a power on operation. The default
value is 1.
lu ci Field cl uster.co n
f At t rib u t e
Descrip t io n
Table A.14, “ HP BladeSystem (Red Hat Enterprise Linux 6.4 and later)” lists the fence device
parameters used by fence_hpbl ad e, the fence agent for HP BladeSystem.
T ab le A.14 . HP Blad eSyst em (Red H at En t erp rise Lin u x 6 .4 an d lat er)
lu ci Field cl uster.co n
f At t rib u t e
Descrip t io n
Name name The name assigned to the HP Bladesystem device connected to
the cluster.
IP Address or
Hostname
i pad d r The IP address or hostname assigned to the HP BladeSystem
device.
IP Port
(optional)
i ppo rt The TCP port to use to connect to the device.
Login l o g i n The login name used to access the HP BladeSystem device. This
parameter is required.
Password passwd The password used to authenticate the connection to the fence
device.
Password
Script
(optional)
passwd _scri
pt
The script that supplies a password for access to the fence
device. Using this supersedes the Passwo rd parameter.
Force
Command
Prompt
cmd _pro mpt The command prompt to use. The default value is\$.
Fence Device Paramet ers
179