System information
Nov 27 2008  Copyright RED Digital Cinema 
55 
DISPLAY: This menu permits specific elements of the GUI to be disabled. 
Selections are – SHUTTER, LENS DATA, EVF MENU, STATUS and GREY SCALE 
Shutter: When checked, displays frame rate and sensor status on GUI upper edge. Also allows 
the user to choose if camera shutter value is reported in Degrees or 1/Seconds format. 
Note: Shutter values are always input in 1/seconds format, irrespective of this choice. 
Lens Data: When checked displays focus / zoom / iris data on GUI mid-upper edge. Also al-
lows the user to choose if Distance is reported in Feet or Meters. 
EVF Menu: When checked displays EVF menus data on left edge of camera GUI 
Status: When checked, displays media, exposure and audio status on GUI lower edge. 
Grey Scale: When checked, displays an 11 step grey scale on GUI right edge. 
Note: Disabling a GUI element disables it on all monitor outputs, and disabling the EVF 
Menu display also disables the EVF menu controls. 
MAINTENANCE 
This sub-menu defines how the cooling fan behaves, and enables software updates. 
Fan Sub Menu: specifies how the cooling fan operates.  
The camera's fan speed can be changed depending on the ambient air temperature and re-
cording application. The default setting is AUTO 
Auto: This setting combines VARIABLE speed fan operation while not recording, with SILENT 
mode when in record. This mode is recommended for extended duration dialog recordings. 