MSDS
_____________________________________________________________________________________________
RD-0098 - Lifetime Pro Adhesive Sealant
Revision Date 05-Apr-2013
Protective Equipment and Precautions for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full
protective gear. Use water spray to keep fire-exposed containers cool.
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions, Protective Equipment and Emergency Procedures
Personal Precautions
Wear protective clothing as described in Section 8 of this safety data sheet.
For Emergency Responders
Restrict access to spill area.
Environmental Precautions
Minimize use of water to prevent environmental contamination. Prevent spill or rinse from
contaminating storm drains, sewers, soil or groundwater.
Methods and Material for Containment and Cleaning Up
Methods for Containment
Prevent further leakage or spillage if safe to do so. Use absorbent material to contain spill.
Methods for Cleaning Up
Sweep up absorbed material and shovel into suitable containers for disposal. Wash area
with soap and water. For waste disposal, see section 13 of the SDS.
7. HANDLING AND STORAGE
Precautions for Safe Handling
Advice on Safe Handling
Avoid breathing vapors. Use only with adequate ventilation. Open windows & doors to
ensure fresh air cross-ventilation during application and curing. Wash thoroughly with soap
and water after handling. Avoid contact with skin, eyes or clothing. While handling product
keep out of reach of childrens and pets.
Conditions for Safe Storage, Including any Incompatibilities
Storage Conditions
Close container after each use. Store containers away from excessive heat & freezing. Do
not store @ temperatures above 120 ° F. To maximize shelf life, store @ temperatures
below 26C (80F).
Incompatible Materials
Oxidizers. Strong acids.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Exposure Guidelines
Exposure guidelines / protective equipment are for routine handling and accidental spills
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Ammonium Hydroxide
7664-41-7
STEL: 35 ppm
TWA: 25 ppm
TWA: 50 ppm
TWA: 35 mg/m
3
(vacated) STEL: 35 ppm
(vacated) STEL: 27 mg/m
3
IDLH: 300 ppm
TWA: 25 ppm
TWA: 18 mg/m
3
STEL: 35 ppm
STEL: 27 mg/m
3
_____________________________________________________________________________________________
Appropriate Engineering Controls
Page 3 / 8
Engineering Controls
Ventilation must be adequate to maintain the ambient workplace atmosphere below the
exposure limit(s) outlined in the SDS.
Individual Protection Measures, such as Personal Protective Equipment