SDS
Page 3 / 8
RD-0157 - Sealant
Revision Date 01-Oct-2017
Protective Equipment and Precautions for Firefighters
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full
protective gear. Use water spray to keep fire-exposed containers cool.
Personal Precautions, Protective Equipment and Emergency Procedures
Personal Precautions Wear protective clothing as described in Section 8 of this safety data sheet.
For Emergency Responders Restrict access to spill area.
Environmental Precautions Minimize use of water to prevent environmental contamination. Prevent spill or rinse from
contaminating storm drains, sewers, soil or groundwater.
Methods and Material for Containment and Cleaning Up
Methods for Containment Prevent further leakage or spillage if safe to do so. Use absorbent material to contain spill.
Methods for Cleaning Up Sweep up absorbed material and shovel into suitable containers for disposal. Wash area
with soap and water. For waste disposal, see section 13 of the SDS.
Precautions for Safe Handling
Advice on Safe Handling Avoid breathing vapors. Use only with adequate ventilation. Open windows & doors to
ensure fresh air cross-ventilation during application and curing. Wash thoroughly with soap
and water after handling. Avoid contact with skin, eyes or clothing. While handling product
keep out of reach of childrens and pets.
Conditions for Safe Storage, Including any Incompatibilities
Storage Conditions Close container after each use. Store containers away from excessive heat & freezing. Do
not store @ temperatures above 120 ° F. To maximize shelf life, store @ temperatures
below 26C (80F).
Incompatible Materials Oxidizers. Strong acids.
Exposure Guidelines Exposure guidelines / protective equipment are for routine handling and accidental spills
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Ammonium Hydroxide
7664-41-7
STEL: 35 ppm
TWA: 25 ppm
TWA: 50 ppm
TWA: 35 mg/m
3
(vacated) STEL: 35 ppm
(vacated) STEL: 27 mg/m
3
IDLH: 300 ppm
TWA: 25 ppm
TWA: 18 mg/m
3
STEL: 35 ppm
STEL: 27 mg/m
3
Appropriate Engineering Controls
Engineering Controls Ventilation must be adequate to maintain the ambient workplace atmosphere below the
exposure limit(s) outlined in the SDS.
Individual Protection Measures, such as Personal Protective Equipment
6. ACCIDENTAL RELEASE MEASURES
7. HANDLING AND STORAGE
8. EXPOSURE CONTROLS/PERSONAL PROTECTION