Conditions for safe storage, including any incompatibilities
Storage Conditions
Stable under normal conditions of handling, use & storage. Store containers in a cool, dry
location, away from direct sunlight & high temperatures. Protect from freezing. Store away
from incompatible materials (caustics & oxidizers). Close container after each use & keep
tightly closed when not in use. To maximize shelf life, store @ temperatures below 26C
(80F).
Incompatible Materials
Strong bases. Oxidizing agents.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Exposure Guidelines
Exposure guidelines / protective equipment are for routine handling and accidental spills
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Calcium Carbonate
1317-65-3
-
TWA: 15 mg/m
3
total dust
TWA: 5 mg/m
3
respirable
fraction
(vacated) TWA: 15 mg/m
3
total
dust
(vacated) TWA: 5 mg/m
3
respirable fraction
TWA: 10 mg/m
3
total dust
TWA: 5 mg/m
3
respirable dust
Titanium Dioxide
13463-67-7
TWA: 10 mg/m
3
TWA: 15 mg/m
3
total dust
(vacated) TWA: 10 mg/m
3
total
dust
IDLH: 5000 mg/m
3
Soda lime borosilicate glass
65997-17-3
TWA: 1 fiber/cm3 respirable
fibers: length >5 µm, aspect ratio
>=3:1, as determined by the
membrane filter method at
400-450X magnification [4-mm
objective], using phase-contrast
illumination
TWA: 5 mg/m
3
inhalable fraction
-
-
Ammonium Hydroxide
7664-41-7
STEL: 35 ppm
TWA: 25 ppm
TWA: 50 ppm
TWA: 35 mg/m
3
(vacated) STEL: 35 ppm
(vacated) STEL: 27 mg/m
3
IDLH: 300 ppm
TWA: 25 ppm
TWA: 18 mg/m
3
STEL: 35 ppm
STEL: 27 mg/m
3
Petroleum Hydrocarbon
64742-48-9
ACGIH TWA: 5 mg/m
3
; ACGIH
STEL: 10 mg/m
3
-
-
Appropriate engineering controls
Engineering Controls
Ventilation must be adequate to maintain the ambient workplace atmosphere below the
exposure limit(s) outlined in the SDS. Provide appropriate local exhaust ventilation if
material is to be sanded.