Specifications

7
Multiple ArcPower 360 installation:
Connect the DMX output of the rst ArcPower 360 with the DMX input of the next ArcPower 360. Always con-
nect one output with the input of the next ArcPower 360 until all xtures are connected.In this way,up to 32
xtures can be chained together.
At the last ArcPower 360 the data link has to be terminated with a terminator. A termination plug is simply a
RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).Plug terminator in the DMX output
of the last ArcPower 360.
Maximum number of LEDs connected to the one zone of the ArcPower 360 is 36 in RGB mode (12 Leds per
colour) and 42 in RGBW mode.
Maximum possible number of LED modules connected to the one zone of the ArcPower 360:
Model
total
LEDs
Red
LEDs
Green
LEDs
Blue
LEDs
White
LEDs
Max.number
of connected
modules
ArcLine 12 RGB 12 4 4 4 - 3
ArcLine 24 RGB 24 8 8 8 - 1
ArcLine 36 RGB 36 12 12 12 - 1
ArcLine Optic 12 RGB 12 4 4 4 - 3
ArcLine Optic 24 RGB 24 8 8 8 - 1
ArcLine Optic 36 RGB 36 12 12 12 - 1
ArcSource 3 RGB 3 1 1 1 - 12
ArcSource 6 RGB 6 2 2 2 - 6
ArcSource 12 RGB 12 4 4 4 - 3
ArcSource 7 RGBW 7 2 2 2 1 6
Note: You cannot combine RGB and RGBW modules (e.g. ArcSource 6 RGB and ArcSource 7 RGBW)
each other as white LEDs will not light.