Specifications
4
3.Description of the ArcPower 360
RJ45 socket LED zone Output
Front view of the socket:
DMX Input DMX Output
RS232 Output
Canon 9-pin male
Front view of the socket:
4.Installation
4.1.Connection to the mains
The ArcPower 360 is equipped with auto-switching power supply that automatically adjusts to any 50/60Hz AC
power source from 100-240 Volts.
Carefully prepare the end of the the supply cord and t a suitable plug.A 3-prong grounding-type plug must be
1 - Control board Indicator
2 - Power indicator
3 - DMX Output
4 - DMX Input
5 - RS 232 Output
6 - LED Zone 1 output
7 - LED Zone 2 output
8 - LED Zone 10 output
9 - Fuse holder
10 - Power Cord
Pin 1: Not connected Pin 5: Not connected
Pin 2: Not connected Pin 6: Data +
Pin 3: Not connected Pin 7: Data -
Pin 4: Not connected Pin 8: GND
Pin 1: Red LED + Pin 5: Red LED -
Pin 2: Green LED + Pin 6: Green LED -
Pin 3: Blue LED + Pin 7: Blue LED -
Pin 4: White LED + Pin 8: White LED -
Pin 1: Not connected
Pin 2: Received Data
Pin 3: Transmitted Data
Pin 4:
Pin 5: Signal Ground
Pin 6:
Pin 7:
Pin 8:
Pin 9: Not connected
Pin 1: Not connected Pin 5: Not connected
Pin 2: +12V Pin 6: Data +
Pin 3: Not connected Pin 7: Data -
Pin 4: Not connected Pin 8: GND