User manual

P a g e | 9
XXPRESS
USER MANUAL - 1.1
4 Technical Specification
Model Type
Model Name
Model No
xxpress
XP-1001-01-1
Physical Unit Properties
Dimensions (W x D x H)
Weight
300 mm x 520 mm x 315 mm
35 kg
Mains Supply
Power Cord Rating
Inlet Module Type
Supply Voltage
Supply Frequency Range
Power Consumption
Fuse Ratings and Sizes
Mains Supply capability
IEC C13, 3-Core, 10A min
IEC C14, DPST, Single Fuse
230 VAC ±10%
50 Hz ±5%
1000 W max
T8AH 250V 20x5mm
The power for this unit must come from
a stable mains supply. Do not power
from inverters, frequency convertors, or
generators. (See Section 5 for further
details)
Operating Environment
Temperature Range
Relative Humidity Range
Maximum Operating Altitude
+18 to +30 °C
(Ambient temperatures above 25°C
can reduce the rate of cooling)
20% to 80% non-condensing
2000 m above sea-level
Storage and Transportation
Temperature Range
Relative Humidity Range
-10 to +50 °C
20% to 95% non-condensing