After successfully writing the log file to media, viewfinder output(s) will display LOG SAVE COMPLETED.
REDmote will also display this message.
If media is not attached to the camera when attempting to perform a write log request, external monitors
will display NO MEDIA ATTACHED.
NOTE: Log files will be stored as *.txt files in the 1.8” SSD root directory.
SW UPDATE
NOTE: Firmware upgrade currently uses a force upgrade procedure as outlined in APPENDIX A:
UPGRADING CAMERA FIRMWARE.
Update SW initiates a camera software (firmware) update. If a software update is on the attached media,
you will be given the option to upgrade the camera (earlier firmware version shown for reference ONLY).
For complete, detailed procedure, go to APPENDIX A: UPDATING CAMERA FIRMWARE.
CALIBRATION
Sensor calibration is a process where the camera generates a calibration map to correct for pixel
defects and offsets based on current system and environmental settings. This allows you to perform a
Black Shading calibration of the MYSTERIUM X sensor two (2) different ways; Default (at 24 FPS @ 1/48
SEC) or using your current FPS/Exposure settings.
To calibrate the sensor the image needs to be as dark as possible:
At a minimum put a lens cap on the lens (WARNING: Not all lens-caps completely block IR. They are
made to protect the lens, not necessarily to block light...)
Preferably, take of the lens, and use the lens-mount cap provided by RED.