Owner Manual
6
TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
e light will not come on.
1. Light switch is turned o.
2. Fuse is blown or circuit breaker is turned o.
3. Daylight turn-o (photocell) is in eect.
4. e circuit wiring is incorrect, if this is a new
installation.
5. e motion sensor is aimed in the wrong
direction.
6. e outside air temperature is close to the
same as a person’s body heat.
1. Turn light switch on.
2. Replace fuse or turn circuit breaker on.
3. Recheck after dark.
4. Verify wiring is correct.
5. Re-aim the motion sensor to cover the
desired area.
6. Increase the “SENS” setting. See
Seasonal
Changes
on page 5 for more information.
e light comes on during
the day.
1. e motion sensor may be installed in a
relatively dark location.
2. e “ON-TIME” switch is in the “TEST”
position.
1. e light xture is operating normally under
these circumstances.
2. Set the “ON-TIME” switch to the 1, 5, or 20
minute setting.
e light comes on for no
apparent reason.
1. e motion sensor may be sensing small
animals or automobile trac.
2. e “SENS” switch is set too high.
3. e “DUALBRITE” switch is in the 3 hour,
6 hour, or dusk-to-dawn setting.
4. e outside temperature is much warmer or
cooler than a person’s body heat (summer or
winter).
5. e light xture is wired through a dimmer
or timer.
1. Decrease the “SENS” setting or reposition
the motion sensor.
2. Decrease the “SENS” setting.
3. e light xture is operating normally under
these circumstances.
4. Decrease the “SENS” setting. See
Seasonal
Changes
on page 5 for more information.
5. Do not use a dimmer or timer to control the
light xture. Replace the dimmer or timer
with a standard on/o wall switch.
e lights turn o too late
in Dusk-to-Dawn setting.
e light xture may be installed in a relatively
dark location.
Relocate the light xture or use the 3 hour or 6
hour setting.
SPECIFICATIONS
Range ...................................................Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle
.......................................Up to 180°
Power Requirements
.............................120 VAC, 60 Hz
Operating Modes
.................................TEST, MOTION ACTIVATED, and MANUAL MODE
ON-Timer
............................................1, 5, 20 minutes
Test Timer
............................................8 Seconds
Manual Mode Timer
............................Maximum 6 Hours
Sensitivity (SENS)
...............................“LO”, “M”, “HI”
HeathCo LLC reserves the right to discontinue products and to change specications at any time without incurring any
obligation to incorporate new features in products previously sold.
is device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
CAN ICES-005 (B)/NMB-005 (B)