TROUBLESHOOTING GUIDE
SYMPTOM POSSIBLE CAUSE SOLUTION
e light will not come on.
1. Light switch is turned o.
2. Fuse is blown or circuit breaker is turned o.
3. Daylight turn-o (photocell) is in eect.
4. e circuit wiring is incorrect, if this is a new
installation.
5. e motion sensor is aimed in the wrong
direction.
6. e outside air temperature is close to the
same as a persons body heat.
1. Turn light switch on.
2. Replace fuse or turn circuit breaker on.
3. Recheck after dark.
4. Verify wiring is correct.
5. Re-aim the motion sensor to cover the
desired area.
6. Increase the “SENS” setting. See
Seasonal
Changes
on page 5 for more information.
e light comes on during
the day.
1. e motion sensor may be installed in a
relatively dark location.
2. e “ON-TIME” switch is in the “TEST”
position.
1. e light xture is operating normally under
these circumstances.
2. Set the “ON-TIME” switch to the 1, 5, or 20
minute setting.
e light comes on for no
apparent reason.
1. e motion sensor may be sensing small
animals or automobile trac.
2. e “SENS” switch is set too high.
3. e “DUALBRITE” switch is in the 3 hour,
6 hour, or dusk-to-dawn setting.
4. e outside temperature is much warmer or
cooler than a persons body heat (summer or
winter).
5. e light xture is wired through a dimmer
or timer.
1. Decrease the “SENS” setting or reposition
the motion sensor.
2. Decrease the “SENS” setting.
3. e light xture is operating normally under
these circumstances.
4. Decrease the “SENS” setting. See
Seasonal
Changes
on page 5 for more information.
5. Do not use a dimmer or timer to control the
light xture. Replace the dimmer or timer
with a standard on/o wall switch.
e lights turn o too late
in Dusk-to-Dawn setting.
e light xture may be installed in a relatively
dark location.
Relocate the light xture or use the 3 hour or 6
hour setting.
SPECIFICATIONS
Range ...................................................Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle
.......................................Up to 180°
Power Requirements
.............................120 VAC, 60 Hz
Operating Modes
.................................TEST, MOTION ACTIVATED, and MANUAL MODE
ON-Timer
............................................1, 5, 20 minutes
Test Timer
............................................8 Seconds
Manual Mode Timer
............................Maximum 6 Hours
Sensitivity (SENS)
...............................“LO”, “M”, “HI”
HeathCo LLC reserves the right to discontinue products and to change specications at any time without incurring any
obligation to incorporate new features in products previously sold.
is device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
CAN ICES-005 (B)/NMB-005 (B)