Assembly & Installation Instructions
ASSEMBLING & INSTALLATION INSTRUCTIONS 
The drawing shown may not exactly match the product enclosed. 
However, the installation instructions do apply to this product. 
  WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER. 
  ATTENTION! COUPER LE COURANT AU FUSIBLE OU UN DISJONCTEUR. 
ASSEMBLING THE FIXTURE (Fig.2) 
1.  Attach the column(A) to the coupling of the lamp body(B), by turn it clockwise until 
tighten. 
2.  Attach the check ring(E) insert to the socket wrench(F), attach the clear 
glass(C) and opal glass(D) to the lamp holder, lock them securely with the socket 
wrench(F), then remove the socket wrench and save it. 
3.  Install the light bulbs(not included) in accordance with the fixture’s specifications. 
NOTE: DO NOT EXCEED THE SPECIFIED WATTAGE! 
** If you not need assembly the fixture loop, 
** Please pause and refer to Fig. 2.1. 
1.  Take out the bottom loop of the canopy and take the loop of lamp body , then take the 
canopy to the lamp body, lock it with the lock washer and hex nut until tight. 
2.  Attach the lamp body to the ceiling, lock it securely with the ball nuts.   
HANGING THE FIXTURE (Fig.1) 
1.  Shut off the power at the circuit breaker and remove old fixture from ceiling, including 
the old single bar. 
2.  Carefully unpack new fixture and lay all the parts on a clear surface. 
3.  Thread the two mounting screws into the pre-drilled holes in the Mounting plate 
spaced the same distance apart as the holes in the canopy. Attach the Mounting plate 
to the Junction Box with the two Junction Box Screws as shown. The side of the 
Mounting plate marked "GND" must face to out. The junction box is not included. 
4.  By measuring, determine correct number of links needed for proper hanging height. 
Using proper chain pliers disconnect and discard remaining chain. 
5.  Lace the fixture wires through the chain. 
6.  Open the end link of the chain and hang the loop at the ceiling and fixture body. Close 
the link. 
7.  Feed the fixture wires through the loop of the canopy and pull until taut. 
8.  Slide canopy up flush to ceiling, lock it securely with ball nuts. 
CONNECTING THE WIRES (Fig.3) 
1.  Take the black wire from the ceiling junction box and the smooth wire leg from the 
fixture and twist bare ends together. Twist wire connector onto end of wire until snug. 
2.    Repeat same process with white junction box wire and ribbed wire leg of fixture wire. 
NOTE: Twist wires together in the same direction you twist the wire connector onto 
wires. 
3.    If your junction box has a grounding wire (green or bare copper), attach this wire and 
the bare copper wire from the fixture together as step 1.If junction box has no ground 
wire, attach the bare copper fixture wire to the green ground screw on the mounting 
plate. 
4. Tuck these wire connections neatly into the ceiling outlet box and then raise the 
canopy all the way to the ceiling, lock it securely with ball nuts. 
Your installation is now complete. Return power to the junction 
box and test the fixture. 
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black(Hot)
FIXTURE
WIRES
White or
Ribbed
FIXTURE
WIRES
Bare
Copper
(Ground)
HOUSE
WIRES
White
(Neutral)
HOUSE
WIRES
Green or Bare
Copper(Ground)
FIG.3 
FIG.1
©COPYRIGHT ALL RIGHTS RESERVED. 
Thank you for purchasing a product. 
Need assistance with parts or assembly? Please call customer service 