WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
MOUNTING
MOUNTING
MOUNTING
MOUNTING THE
THE
THE
THE FIXTURE
FIXTURE
FIXTURE
FIXTURE
1. Shut off the power at the fuse box or circuit breaker box.
Remove the old fixture from ceiling, including the single
bar .
2. Carefully unpack your new fixture and lay out all the parts
on a clear area. Take care not to lose any small parts
necessary for installation.
3. Thread end of nipple ( C ) into single bar (D) until snug.Place
lock washer (B) over end of nipple protruding through
single bar and thread hex nut (A) onto nipple until tight.
4. Take this single bar assembly and mount to ceiling junction
box with junction box screws (E). Tighten screws securely
with screwdriver.The side of the single bar marked "GND"
must face out.
5. Hold the pan ( F ) towards the single bar and connect the
electrical wires as follows (See Fig.2). Connect the black
wire from the fixture to the black house (hot) wire; connect
the white wire from the fixture to the white house ( neutral)
wire. Make sure all wire nuts are secured.
You
may wrap
the connections with electrical tape. If your outlet box has
a ground wire (green or bare copper) connects fixture
s
ground wire to it. Other wise attach the bare copper fixture
wire to the green ground screw on the single bar. Tuck the
wire connections neatly into the ceiling junction box as you
are holding the fixture assembly toward the ceiling.
6. Raise p an ( F ) to the junction box, aligning nipple on
single bar with center hole in the p an and lock it securely
with the knurled nut ( G ).
7.
7.
7.
7. Install the light bulbs in accordance with the fixture
s
specifications. DO
DO
DO
DO NOT
NOT
NOT
NOT EXCEED
EXCEED
EXCEED
EXCEED THE
THE
THE
THE MAXIMUM
MAXIMUM
MAXIMUM
MAXIMUM
WATTAGE
WATTAGE
WATTAGE
WATTAGE
RATING!
RATING!
RATING!
RATING!
8. Put the glass shade ( H ) in to the frame ( I ) , Raise the
assembly to the pan(F), aligning small nipple on the pan
with small hole in the frame(I), lock it with the ball nut(J).
Your
Your
Your
Your
installation
installation
installation
installation is
is
is
is now
now
now
now complete.
complete.
complete.
complete. Return
Return
Return
Return power
power
power
power to
to
to
to the
the
the
the
junction
junction
junction
junction box
box
box
box and
and
and
and test
test
test
test the
the
the
the fixture.
fixture.
fixture.
fixture.
Fig.1
Fig.1
Fig.1
Fig.1
H
I
J
Fig.2
Fig.2
Fig.2
Fig.2
MIN
MIN
MIN
MIN 90
90
90
90
SUPPLY CONDUCTORS
Listed
U
L
R
White or
HOUSE
Black
WIRES
(Hot)
Smooth
FIXTURE
WIRES
Black or
Ribbed
WIRES
FIXTURE
Bare Copper(Ground)
FIXTURE
WIRES
Copper
(Ground)
HOUSE
(Neutral)
WIRES
White
Bare
Green or
WIRES
HOUSE

Summary of content (1 pages)