Datasheet

RW-S
Specifications (Core Operating Area)
Input Voltage Range 2:1
Output Voltage Accuracy ±2% max.
Line Voltage Regulation ±0.2% typ.
Load Voltage Regulation (10% to 100% full load) ±0.5% max.
Minimum Load 10%
(2)
Output Ripple and Noise (20MHz limited) 70mVp-p max.
Operating Frequency 85kHz min. / 100kHz typ.
Efficiency at Full Load See Selection Guide
No Load Power Consumption 250mW max.
Isolation Voltage (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
Isolation Capacitance 40pF min. / 60pF max.
Isolation Resistance 1 GΩ min.
Short Circuit Protection Continuous
Operating Temperature Range (free air convection) -40°C to +80°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight DIP24 7g
SMD 7.7g
Packing Quantity 15 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1034 x 10
3
hours
(+80°C) using MIL-HDBK 217F 186 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1212007 EN60950-1:2006 + A11:2009+A1:2010+A12:2011
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition Medical Report + ISO14971 Risk Assessment
RW-xxxxS
Series
ECONOLINE
DC/DC-Converter
Typical Performance
}
Detailed Information see
Application Notes chapter "MTBF"
RW-1205S
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
RW-2412S
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RW-S series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
REV: 0/2015 E-135www.recom-power.com