Datasheet
Refer to Application Notes
ECONOLINE
DC/DC-Converter
with 3 year Warranty
RUZ
EN-60950-1 Certified
Part Input Output Output Output Efficiency Max
Number Voltage Voltage Voltage Current Capacitive
SIP 7 2kV (VDC) (V1VDC) (V2VDC) (mA) (%) Load
(1)
RUZ-050505 (H) 5 5 5 200/200 70 470µF/470µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RUZ-050505/P, RUZ-050505/HP
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
2 Watt
SIP7
Isolated
Dual Output
Derating-Graph
(Ambient Temperature)
●
Dual Output from a Single Input Rail
●
Input/Output Isolation 1kVDC or 2kVDC
●
Output/Output Isolation 1kVDC
●
Power Sharing on Outputs
●
UL94V-0 Package Material
●
Optional Continuous Short Circuit Protected
●
No External Components Required
●
Efficiency to 85%
Features
Unregulated
Converters
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation ((10% to 100% full load) 15% max.
Output Ripple and Noise (20MHz limited) 150mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 70% min. / 80% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage (tested for 1 second) 1000VDC
Input/Output and Output/Output (rated for 1 minute**) 3200VAC / 60Hz
Isolation Voltage H-suffix (tested for 1 second) 2000VDC
Input/Output H-suffix (rated for 1 minute**) 1000VAC / 60Hz
Output/Output (tested for 1 second) 1000VDC
Isolation Capacitance 40pF min. / 120pF max.
Isolation Resistance 10 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
Relative Humidity 95% RH
Package Weight 2.8g
Packing Quantity 25 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 988 x 10
3
hours
(+85°C) using MIL-HDBK 217F 135 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1109103 EN60950-1:2006 + A12:2011
Selection Guide
}
Detailed Information see
Application Notes chapter "MTBF"
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
The RUZ DC/DC converter offers two independent isolated outputs. Typical applications include
multiple channel circuits where inter-channel isolation is also required.
The /H option offers 2kVDC isolation between input and outputs. The /P option is with continuous
short circuit protection on either or both outputs.
Description
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
REV: 0/2015 www.recom-power.comE-104