Data Sheet
www.recom-power.com
REV.: 1/2018 ECO-4
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RU/RUM
Series
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
PCB
non-conductive black plastic (UL94 V-1)
epoxy, (UL94 V-0)
FR4, (UL94 V-1)
Package Dimension (LxWxH)
RU
RUM
19.65 x 7.0 x 10.2mm
16.55 x 6.0 x 7.7mm
Package Weight 2.7g typ.
Pinning information
Pin # Single
1 +Vin
2 -Vin
4 +Vout 1
5 -Vout 1
6 +Vout 2
7 -Vout 2
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
Pinning information
Pin # Single
1 +Vin
2 -Vin
3 +Vout 1
4 -Vout 1
5 +Vout 2
6 -Vout 2
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
1 2 654 7
1 2 654 7
0.51
1.27
10.2
0.51
+0.10/-0.05
6.0
19.6
6x2.54= 15.242.0
2.54
2.54
4.10
0.25
Marking
Bottom View
Top View
embossed logo
Bottom View
1 2 3 4 5 6
1 2 3 4 5 6
Top View
0.51
1.27 7.7
0.51
+0.10/-0.05
6.0
16.55
5x2.54 = 12.701.9 2.54
2.54
4.10
0.25
±0.05
Marking
embossed logo
Dimension Drawing (mm)
SIP7 Package
RU
RUM
SIP6 Package
Recommended Footprint Details
Recommended Footprint Details