Datasheet

www.recom-power.com
REV.: 3/2019 ECO-3
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal Vin, full load unless otherwise specified)
RSE
Series
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range without derating (see graph) -40°C to +75°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.05%/°C
Operating Altitude 5000m
Operating Humidity non-condensing 5% - 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B.
+25°C
+75°C
2289 x 10
3
hours
781 x 10
3
hours
Vibration MIL-STD 202G
100
80
60
40
20
0
-40 0
50
75
100
150
Output Power [%]
Ambient Temperature [°C]
Derating Graph
(@ Chamber and natural convection 0.1m/s)
+Vin
-Vin
LOAD
D
surge
C
1
Fuse
Surge Protection Circuit according to EN61000-4-5, Criteria A
nom. Vin TVS C1
5VDC P4SMAJ11A N/A
24VDC P4SMAJ36A 220µF/100V
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety
E224736-A48
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2nd Ed. 2014
Audio/Video, information and communication technology equipment - Safety
requirements
UL62368-1, 2nd Edition, 2014
CSA C22.2 Nr. 62368-1-14, 2nd Ed. 2014
Audio/Video, information and communication technology equipment - Safety
requirements (CB Scheme)
L0339m37-CB-1-B1 IEC/EN62368-1, 2nd Edition, 2014
RoHS 2+ RoHS 2011/65/EU + AM2015/863
continued on next page
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: An input fuse is required if the mains supply is not over-current protected. Recommended fuse: T2A slow blow type