Datasheet

www.recom-power.com
REV.: 3/2019 ECO-2
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal Vin, full load unless otherwise specified)
RSE
Series
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP) below 100mW continuous, auto recovery
Isolation Voltage
(5)
I/P to O/P tested for 1 second 2kVDC
Isolation Resistance 1GW min.
Isolation Capacitance 100pF max.
Insulation Grade functional
continued on next page
REGULATIONS
Parameter Condition Value
Output Accuracy 0-100% load ±2.0% max.
Line Regulation low line to high line, full load ±0.2% max.
Load Regulation 0% to 100% load ±0.5% max.
Efficiency vs. Load
RSE-0505S/H2
RSE-0505S/H2
RSE-2405S/H2
RSE-2405S/H2
Accuracy vs. Load
Efficiency [%]
Output Current [A]
0
0
20
40
60
80
100
0.1 0.2 0.3 0.4
4.5Vin
5Vin
7Vin
9Vin
Accuracy [%]
Output Current [A]
0
0
0.2
0.1
0.3
0.4
0.5
0.6
0.1 0.2 0.3 0.4
Efficiency [%]
Output Current [A]
0
0
20
40
60
80
100
0.1 0.2 0.3 0.4
18Vin
20Vin
24Vin
30Vin
36Vin
Accuracy [%]
Output Current [A]
0
0
0.1
0.2
0.3
0.4
0.5
0.1 0.2 0.3 0.4