Datasheet

www.recom-power.com
REV.: 7/2018 ECO-7
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
RS6
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter Type Value
Material
case
potting
non conductive plastic (UL94V-0)
epoxy (UL94V-0)
Dimension (LxWxH) 21.8 x 9.2 x 11.1mm
Weight 4.0g
Dimension Drawing (mm)
Bottom View
Top View
0.50
3.20 11.1
0.51
+0.10/-0.05
9.2
1.00 Ø +0.15/-0
21.8
7x2.54= 17.782.00
4.10
2.54
2.54
1 2 3 65 7 8
1 2 3 65 7 8
Marking
embossed logo
0.25
±0.05
Recommended Footprint Details
Pin Connections
Pin # Single Dual
1 -Vin -Vin
2 +Vin +Vin
3 CTRL
(7)
CTRL
(7)
5 Trim NC
6 +Vout +Vout
7 -Vout Com
8 NC -Vout
NC= no connection
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Pin dimension: ±0.1mm
Pin pitch: ±0.25mm
Notes:
Note7: This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’
the converter is OFF and when the pin is high ‘Z’ the converter is ON. There is no allowed low state for this pin
PACKAGING INFORMATION
Parameter
Value
Packaging Dimension (LxWxH) tube 520.0 x 18.2 x 11.2mm
Packaging Quantity 22pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity non-condensing 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
unauthorized
use of RECOM products in such safety-critical applications.