Datasheet
www.recom-power.com
REV.: 7/2018 ECO-5
DC/DC Converter
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm up unless otherwise specified)
RS6
Series
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) below 100mΩ continuous, automatic revovery
Over Load Protection (OLP) 150% load, continuous, automatic recovery
Isolation Voltage
(5)
I/P to O/P
tested for 1 second
rated for 1 minute
2kVDC
1.6kVDC
Isolation Capacitance 110pF max.
Isolation Resistance 1GΩ typ.
Isolation Grade functional
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range
(6)
full load (see graph) -40°C to +75°C
Maximum Case Temperature +105°C
Temperature Coefficient ±0.02%/°C
Operating Humidity non-condensing 5% - 95% RH max.
Vibration MIL-STD-202G
MTBF according to MIL-HDBK-217F, G.B. +25°C 1776 x 10
3
hours
SAFETY AND CERTIFICATIONS
Certificate Type Report / File Number Standard
Information Technology Equipment, General Requirements for Safety (LVD) L0339m26-B1-L EN60950-1, 2nd Endition AM2 , 2013
Audio/video, information and communication technology equipment - Safety requirements
L0339m27-B1-L ICE/EN62368-1, 2014
RoHS2 RoHS-2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement
with external filter
(see filter suggestions)
EN55022, Class A
EN55022, Class B
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN55024, 2010
continued on next page
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90
8575
110100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Notes:
Note6: Derating Graph is referring to RS6-0505S. For more details, please contact our technical support service at TechsupportAT@recom-power.com
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Derating Graph
(@ Chamber and natural convection 0.1m/s)